B2J03 — Single-channel serial I/O
Compact remote signal and relay control.
Choose the module by signal direction, channel count, relay or transistor output, electrical isolation, protocol, supply and enclosure or mounting option.
Compact remote signal and relay control.
Sensor acquisition with PWM-capable outputs.
Two serially controlled transistor channels.
4–28 digital inputs by model.
2–14 isolated outputs by model.
Compact mixed input/output stations.
Related Modbus TCP to Modbus RTU gateway.
Use when switches and sensor states must be collected remotely without local output channels.
Use when the remote station must switch relay or transistor outputs. D3J-02XX provides 2–14 outputs by model.
Use mixed D3J-03xx stations for local input/output. Use D2J-0701 when Ethernet must bridge to a serial network.
Protocol boundary: RS-485 describes the electrical interface; Modbus RTU describes the message protocol. These are non-safety automation modules.
Use the model links to check the terminal drawing and register map for the actual order. The checks below identify documents and decisions to confirm; they do not add electrical ratings or guarantee optional functions.
| Series | Role | Best-fit task | Confirm before ordering |
|---|---|---|---|
| B2J03 | Single-channel serial I/O | Compact remote signal and relay control | Input electrical interface, commanded output function and corresponding register addresses. |
| B2J0401 | Analog/digital I/O | Sensor acquisition with PWM-capable outputs | Analog/digital terminal use, signal scaling and the exact output option and register map. |
| B2J0405 | Dual-channel transistor output | Two serially controlled transistor channels | Ordered transistor-output variant, load requirements and any required PWM settings. |
| D3J-01xx | Digital input | 4–28 digital inputs by model | Exact input count, input wiring and the electrical limits for each collected signal. |
| D3J-02XX | Relay / transistor output | 2–14 isolated outputs by model | Exact output count, relay or transistor variant and whether the required pulse function is documented. |
| D3J-03xx | Combined digital I/O | Compact mixed input/output stations | The selected input/output combination and any required local process-control behaviour. |
| D2J-0701 | Ethernet-to-serial gateway | Related Modbus TCP to Modbus RTU gateway | Gateway mode, Ethernet/serial endpoints and any pin multiplexing in the ordered configuration. |
B2J0401 analog/digital I/O and B2J0405 transistor-output modules are different ordering models. Similar appearance or overlapping functions do not establish interchangeability: compare the complete order code, output option, terminal drawing and firmware/register-map revision.
For a network-bridging task, start with the D2J-0701 Ethernet-to-serial gateway. For field signal acquisition or switching, start with the appropriate D3J input, output or combined-I/O model above; a TCP/RTU gateway is not itself a substitute for those field channels.
Separate inputs, relay outputs, transistor outputs, analog points and pulse-capable channels before selecting a model.
Confirm baud rate, addressing, termination, cable length, grounding and whether Ethernet conversion is required.
DIN-rail mounting, bare board and enclosure are ordering options across these ranges; verify the exact supplied format.
It is a remote output module whose relay or transistor channels are commanded over an RS-485 link, commonly using Modbus RTU. RS-485 is the physical interface; Modbus is the communication protocol.
The D3J-02XX family is treated here according to the confirmed product range: 2–14 isolated outputs depending on model. Its historical URL wording is not a reliable product specification.
Its primary role is an Ethernet-to-serial gateway. It is listed as a related gateway, not as a substitute for a D3J remote I/O station.
No. These modules are for ordinary monitoring and automation. Safety functions require components and architectures specifically documented for the required safety performance.